MIL-PRF-83812D
(Application for copies should be addressed to the Tire and Rim Association, Inc., 175 Montrose
West Ave. Suite150, Copley, OH 44321)
UNDERWRITERS LABORATORIES INC.
UL 299
Dry Chemical Fire Extinguishers
UL 711
Rating and Fire Testing of Fire Extinguishers
(UL documents may be obtained at https://ulstandardsinfonet.ul.com/catalog or hardcopies and
CD s can be found at COMM 2000 1414 Brook Drive, Downers Grove, IL 60515)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a
conflict between the text of this document and the references cited herein, (except for related
specification sheets), the text of this document takes precedence. Nothing in this document,
however, supersedes applicable laws and regulations unless a specified exemption has been
obtained.
3. REQUIREMENTS
3.1 First article. When specified (see 6.2), one forklift sample shall be subjected to first article
inspection in accordance with 4.2.
3.2 Forklift description. The forklift shall be the supplier s standard, commercial, rigid or
articulated frame forklift, or a front end loader modified with a forklift attachment in place of the
scoop bucket. If the forklift is rigid frame type, it shall have operator selected 2-wheel/4-wheel
crab steering, and operator selected 2-wheel/4-wheel drive. If the forklift is the articulated frame
type, it shall have operator selected 2-wheel/4-wheel drive, except as noted (see 3.9.2).
Whatever type is furnished, it shall meet all requirements specified in this document. The
forklift shall be air transportable in C-130, C-17 and C-5 aircraft, as a reference only, refer to
MIL-HDBK-1791. The forklift shall be equipped with, but not limited to, instruments,
components and accessories that are standard on the commercial product, whether specified
herein or not.
3.3 Design and construction. The forklift shall be designed and constructed so that no parts will
work loose in service. They shall be built to withstand the strains, jars, vibrations, and other
conditions incident to shipping, storage, installation, and service. They shall be weatherproof
and designed to prevent the intrusion of water and sand into critical operating components.
Unless suitably protected against electrolytic corrosion, dissimilar metals shall not be in intimate
contact with each other.
3.3.1 Materials, protective coatings, and finish.
3.3.1.1 Protective coatings. Materials that deteriorate when exposed to sunlight, weather, or
operational conditions normally encountered during the service life of the item shall not be used
or shall have means of protection against such deterioration that does not prevent compliance
with the performance requirements specified herein. Protective coatings that chip, crack, or scale