MIL-PRF-83812D
1-1/2 inch high letters on the lifting arms, mast, or front of forklift
b. "NO RIDERS" in 2 inch high letters on each side of forklift
3.3.3 Identification and information plates.
3.3.3.1 Identification plate. An identification plate in accordance with MIL-STD-130 shall be
securely attached to the forklift in a readily accessible location. The identification plate shall
contain the following information: nomenclature, make and model, manufacturer s serial
number (VIN), registration number, asset NSN number, vehicle curb weight (lbs), maximum
payload (lbs), gross vehicle weight (lbs), delivery date, manufacturer s name, Commercial and
Government Entity (CAGE) code, date of warranty expiration, contract number, and "US
Property".
3.3.3.2 Transportation data plate. A transportation data plate shall be securely attached to the
forklift in a readily accessible location. The plate shall contain at least the following
information:
a. Side and rear silhouette views of the forklift
b. Horizontal and vertical location of the center of gravity of the forklift in air
transportable configuration, marked on the silhouette views
c. Shipping weight (pounds)
d. Loading cubage (inches^3)
e. Overall height, width, and length (inches)
f. Front and rear axle loads (pounds)
g. Tiedown information
3.3.3.3 Instruction plates. All warning and instruction plates normally installed by the forklift
manufacturer, describing procedures or safety items shall be included.
3.3.4 Safety. The forklift shall conform to the applicable requirements of
ANSI/ITSDF B56.6-2005, SAE J98, and OSHA standards in effect at the time of issue of the
solicitation. All surface areas subject to personnel standing or walking shall have a nonskid,
tread-plate, or expanded metal surface. A commercial fire extinguisher shall be mounted on the
forklift in an easily accessible location. The fire extinguisher shall be a minimum 2-1/2 pound
capacity ABC type, or equivalent. The fire extinguisher shall be UL299 listed and UL711 tested.
3.3.4.1 Component protection. All space in which work is performed during operation, service,
and maintenance shall be free of hazardous protrusions, sharp edges, or other features which may
cause injury to personnel. All rotating and reciprocating parts and all parts subject to high
operational temperatures or subject to being electrically energized, that are of such nature or so
located as to be hazardous to personnel, shall be guarded or insulated to eliminate the hazard.
3.3.4.2 Foreign object damage (FOD). All loose metal parts, such as pins or connector covers,
shall be securely attached to the forklift with wire ropes or chains. "Dog tag" style beaded chains