MIL-PRF-83817B
UNDERWRITERS LABORATORIES INC.
UL 299 Dry Chemical Fire Extinguishers
UL 711 Rating and Fire Testing of Fire Extinguishers
(UL documents may be obtained online at https://ulstandardsinfonet.ul.com/catalog or hardcopies
and CD s can be found at COMM 2000 1414 Brook Drive, Downers Grove, IL 60515)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a
conflict between the text of this document and the references cited herein, (except for related
specification sheets), the text of this document takes precedence. Nothing in this document,
however, supersedes applicable laws and regulations unless a specified exemption has been
obtained.
3. REQUIREMENTS.
3.1 First article. When specified (see 6.2), one sample shall be subjected to first article
inspection in accordance with 4.2.
3.2 Forklift description. The forklift shall be the supplier s standard, commercial, forklift. The
forklift shall meet all requirements specified in this document. Unless otherwise specified
herein, or inherently restricted due to a movement capabilities requirement, the use of outriggers
to meet these requirements is acceptable. The forklift shall be air transportable in C-130, C-17,
and C-5 aircraft, as a reference only, refer to MIL-HDBK-1791. The forklift shall be equipped
with, but not limited to, instruments, components, and accessories that are standard on the
commercial product, whether specified herein or not.
3.3 Design and construction. The forklift shall be designed and constructed so that no parts will
work loose in service. They shall be built to withstand the strains, jars, vibrations, and other
conditions incident to shipping, storage, installation, and service. They shall be weatherproof
and designed to prevent the intrusion of water and sand into critical operating components.
Unless suitably protected against electrolytic corrosion, dissimilar metals shall not be in intimate
contact with each other.
3.3.1 Materials, protective coatings, and finish.
3.3.1.1 Protective coatings. Materials that deteriorate when exposed to sunlight, weather, or
operational conditions normally encountered during the service life of the forklift shall not be
used or shall have means of protection against such deterioration that does not prevent
compliance with the performance requirements specified herein. Protective coatings that chip,
crack, or scale with age or extremes of climatic conditions or when exposed to heat shall not be
used. Fasteners, handles, and fittings used in the assembly of the forklift shall also be primed
and painted.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business