g. Tiedown information
3.3.3.3 Instruction plates. All warning and instruction plates normally installed by the forklift
manufacturer, describing procedures or safety items shall be included.
3.3.3.4 Load Chart. A corrosion resistant plate, showing the load capacity of the forklift at all
boom extensions and lift heights shall be permanently installed in a location clearly visible to the
operator.
3.3.4 Safety.
The forklift shall conform to the applicable requirements of
ANSI/ITSDF B56.6-2005, SAE J98, and OSHA standards in effect at the time of issue of the
solicitation. All surface areas subject to personnel standing or walking shall have a nonskid,
tread-plate, or expanded metal surface. A commercial fire extinguisher shall be mounted on the
forklift in an easily accessible location. The fire extinguisher shall be a minimum 2-1/2 pound
capacity ABC type, or equivalent. The fire extinguisher shall be UL299 listed and UL711 tested.
3.3.4.1 Component protection. All space in which work is performed during operation, service,
and maintenance shall be free of hazardous protrusions, sharp edges, or other features which may
cause injury to personnel. All rotating and reciprocating parts and all parts subject to high
operational temperatures or subject to being electrically energized, that are of such nature or so
located as to be hazardous to personnel, shall be guarded or insulated to eliminate the hazard.
3.3.4.2 Foreign object damage (FOD). All loose metal parts, such as pins or connector covers,
shall be securely attached to the forklift with wire ropes or chains. "Dog tag" style beaded chains
shall not be provided. Removable panels, if provided, shall be attached with captive fasteners.
Tire valve stem caps shall be made of plastic.
3.3.4.3 Seatbelts and operator s restraint.
3.3.4.3.1 Seat belt. An operator s seat belt with a retractor shall be installed. The seat belt must
conform to SAE J386, Type One. However, the installation of a lap belt alone will not be
considered as adequate occupant restraint.
3.3.4.3.2 Additional restraint. Additional restraint devices designed to ensure the operator s
body remains entirely within the protection of the frame and overhead guard in the event of tip
over will also be provided. The restraint system shall not interfere with operator access or
mobility, or the vehicles operation.
3.3.4.3.3 Decal. A warning decal shall be provided advising of the hazards of tip over and the
importance of using the restraint system.
3.3.4.4 Sound levels. The sound level measured at the operator s station should not exceed 84
dB(A). If the sound level is above 84 dB(A), the contractor shall provide a hazardous noise
warning plate stating that operator s hearing protection is required when operating this forklift.